1.Product Description
EI76 electronic power transformer works based on the principle of electromagnetic induction and power electronic conversion technology. Traditional electromagnetic transformer uses alternating magnetic field to transfer energy between primary and secondary windings to realize voltage transformation. The electronic power transformer on this basis, first through the power electronic converter will input alternating current into direct current, and then through the control circuit to adjust the amplitude, phase and other parameters of the direct current, and then through another power electronic converter will be the direct current inverter for the required characteristics of the alternating current output. This method not only realizes voltage conversion, but also regulates the power quality.
1. Strong power quality adjustment ability: it can monitor and adjust the amplitude, phase and frequency of the output voltage in real time, effectively compensate for voltage fluctuation, flicker, harmonics and other power quality problems, and provide a stable, high-quality power supply for sensitive loads. For example, in the semiconductor manufacturing workshop which requires high voltage stability, electronic power transformer can ensure that the production equipment is not affected by voltage fluctuation, and improve the product yield rate.
2. Electrical isolation and flexible transformation: not only has the traditional transformer electrical isolation function, to protect the personnel and equipment safety, but also can realize a variety of voltage levels, different phases between the flexible transformation. For example, in some special industrial occasions, it can convert three-phase power into single-phase power, or realize the conversion of special voltage levels to meet the needs of different equipment.
3. Small size, light weight: with the help of high-frequency power electronic conversion technology, can improve the working frequency of the transformer, thus reducing the size of the core and winding, so that the overall volume and weight compared with the traditional transformer is greatly reduced. This is a significant advantage in applications with strict space and weight constraints, such as electric vehicle charging piles and aerospace equipment.
4. Intelligent control and monitoring: through advanced control algorithms and communication technology, electronic power transformers can realize remote monitoring, fault diagnosis and automatic protection functions. The operation and maintenance personnel can grasp the equipment operation status in real time, discover and deal with potential faults in time, and improve the system reliability and operation and maintenance efficiency.
Parameter | Description | Typical Values / Ranges |
Rated Power | The maximum continuous power the EPT can handle under normal operating conditions. | Varies widely, e.g., from a few watts for small - scale applications to several megawatts for high - power systems. |
Input Voltage | The voltage level of the incoming electrical supply. | Common values: 110V, 220V, 380V (AC), with some transformers designed for a wide input voltage range like 90 - 264V (AC). |
Output Voltage | The voltage provided at the output terminals of the EPT. | Depends on the application, can be as low as a few volts for electronics or several kilovolts for industrial applications. |
Voltage Regulation | The change in output voltage from no - load to full - load conditions, expressed as a percentage. | Usually within 1% - 5% for well - designed EPTs. |
Efficiency | The ratio of output power to input power, representing the energy conversion effectiveness. | High - efficiency EPTs can achieve values above 90% - 95%. |
Low frequency transformers | EI | EI14, EI16,EI19, EI24,EI28, EI30, EI35, EI38.5, EI41,EI48, EI57, EI60, EI66, EI74, EI76, EI86, EI96, EI105, EI114 |
![]() |
Brand Name: | ZXY |
Model Number: | ZXY-EI76 |
MOQ: | Negotiable |
Price: | Negotiable |
Packaging Details: | 1000pieces / Carton size:380mm*325mm*345mm |
Payment Terms: | T/T paypal xtransfer |
1.Product Description
EI76 electronic power transformer works based on the principle of electromagnetic induction and power electronic conversion technology. Traditional electromagnetic transformer uses alternating magnetic field to transfer energy between primary and secondary windings to realize voltage transformation. The electronic power transformer on this basis, first through the power electronic converter will input alternating current into direct current, and then through the control circuit to adjust the amplitude, phase and other parameters of the direct current, and then through another power electronic converter will be the direct current inverter for the required characteristics of the alternating current output. This method not only realizes voltage conversion, but also regulates the power quality.
1. Strong power quality adjustment ability: it can monitor and adjust the amplitude, phase and frequency of the output voltage in real time, effectively compensate for voltage fluctuation, flicker, harmonics and other power quality problems, and provide a stable, high-quality power supply for sensitive loads. For example, in the semiconductor manufacturing workshop which requires high voltage stability, electronic power transformer can ensure that the production equipment is not affected by voltage fluctuation, and improve the product yield rate.
2. Electrical isolation and flexible transformation: not only has the traditional transformer electrical isolation function, to protect the personnel and equipment safety, but also can realize a variety of voltage levels, different phases between the flexible transformation. For example, in some special industrial occasions, it can convert three-phase power into single-phase power, or realize the conversion of special voltage levels to meet the needs of different equipment.
3. Small size, light weight: with the help of high-frequency power electronic conversion technology, can improve the working frequency of the transformer, thus reducing the size of the core and winding, so that the overall volume and weight compared with the traditional transformer is greatly reduced. This is a significant advantage in applications with strict space and weight constraints, such as electric vehicle charging piles and aerospace equipment.
4. Intelligent control and monitoring: through advanced control algorithms and communication technology, electronic power transformers can realize remote monitoring, fault diagnosis and automatic protection functions. The operation and maintenance personnel can grasp the equipment operation status in real time, discover and deal with potential faults in time, and improve the system reliability and operation and maintenance efficiency.
Parameter | Description | Typical Values / Ranges |
Rated Power | The maximum continuous power the EPT can handle under normal operating conditions. | Varies widely, e.g., from a few watts for small - scale applications to several megawatts for high - power systems. |
Input Voltage | The voltage level of the incoming electrical supply. | Common values: 110V, 220V, 380V (AC), with some transformers designed for a wide input voltage range like 90 - 264V (AC). |
Output Voltage | The voltage provided at the output terminals of the EPT. | Depends on the application, can be as low as a few volts for electronics or several kilovolts for industrial applications. |
Voltage Regulation | The change in output voltage from no - load to full - load conditions, expressed as a percentage. | Usually within 1% - 5% for well - designed EPTs. |
Efficiency | The ratio of output power to input power, representing the energy conversion effectiveness. | High - efficiency EPTs can achieve values above 90% - 95%. |
Low frequency transformers | EI | EI14, EI16,EI19, EI24,EI28, EI30, EI35, EI38.5, EI41,EI48, EI57, EI60, EI66, EI74, EI76, EI86, EI96, EI105, EI114 |